You have a warehouse with a known clear height and a run of metal pallet boxes that are already loaded. The question on the floor is simple and expensive to get wrong: how many of these can stand on each other before the stack stops being a storage plan and starts being a risk. It is rarely answered by reading one number off a box.
In our project files, per-box load and stacking layer count sit on separate lines of the same specification table, and both are confirmed against one drawing. They answer different questions. This article walks through how the two are specified apart, what has to be true at the interface between two boxes, why floor and centre of gravity decide as much as the steel does, and why a layer count from someone else’s project cannot be transferred to yours.
Layer Count and Per-Box Load Are Approved as Two Separate Line Items
The per-box load is the mass one box carries: the goods inside it, assumed to sit in a defined way (normally uniformly distributed over the bottom). The stacking layer count is a different statement: how many assembled boxes the base frame and the corner columns are designed to carry in a stack, and at what total height. A box can be perfectly strong for its own load and still not be the box you stack five high, because the columns and the feet carry the stack, not the goods.
Project 15730 shows the two values recorded side by side for two different produce handling schemes, with the layer count set by the produce height and the warehouse stack the customer described:
| Parameter | Scheme A (project 15730) | Scheme B (project 15730) |
|---|---|---|
| External size | 1400 x 1100 x 1300 mm | 1100 x 1100 x 800 mm |
| Internal size | 1230 x 960 x 1090 mm | 930 x 960 x 590 mm |
| Empty weight | 123 kg | 82 kg |
| Load per box | 1200 kg | 1000 kg |
| Stacking layers as recorded | 4 | 5 |
| 40HQ loading quantity | 112 pcs | 140 pcs |
Read these as what they are: the values recorded for one project after that customer supplied the goods, the fill height and the intended stack. They are not a catalogue rating for every Mybox build. A different internal height, a different gate layout, a different base, or a heavier and less even load produces a different pair of numbers, and the drawing has to be reissued before either figure can be quoted.

The Stacking Interface Is Decided by Foot-on-Column Seating
A stack is only as upright as its least well seated joint. Each upper box transfers its share of the stack into the columns of the box below through the stacking feet on its base. If a foot lands on a mesh panel, on the edge of a gate, or half on a column, that load goes somewhere the drawing never intended, and the stack leans rather than carries.
The risk notes attached to project 13800 put it directly in the operator’s hands: before the handling equipment is withdrawn, the operator must confirm that the feet of the upper unit have fully landed on the columns of the lower unit. The same notes call for even-speed fork entry and lifting rather than snatching the box, and for periodic checks of the base, columns and welds for bending, distortion or cracked welds, because a damaged column removes exactly the part of the box that makes stacking possible.
Two practical consequences follow. First, casters change the interface: a box standing on swivel casters is not seated on columns in the same way as a fixed-foot box, and mixed stacks of castered and fixed units should not be improvised on the floor. Second, any box whose column has been bent by a forklift is out of the stack until it is inspected, however good the load rating looks on paper.


Floor Condition, Footprint and Centre of Gravity Drive the Real Limit
A loaded stack does not press on the slab evenly. It presses where the bottom box touches the floor, concentrated near the column and foot positions. That means the floor, not only the box, belongs in the calculation: level, free of steps and drainage channels along the stack line, and able to take the concentrated load at those points. We do not survey your slab, and a box drawing cannot certify it; that confirmation belongs to your facility or structural engineer.
Centre of gravity decides the rest. Dense, small parts sitting high in a tall stack raise the combined centre of gravity and put the whole column line under a tipping moment that no load rating describes. Keeping heavy goods in the lower boxes, filling boxes evenly rather than in one corner, and avoiding a tall narrow stack next to an open aisle are ordinary warehouse decisions that change what is safe far more than a few millimetres of steel.
Height also has to be closed out arithmetically: assembled height multiplied by the planned layer count, plus the clearance the handling equipment needs to place and retrieve the top box, must fit under the lowest obstruction. A stack that fits the clear height but not the forklift’s lift and reach is not a stack you can service.


Why Another Project’s Layer Count Cannot Be Copied Across
Project 15730 records 4 layers on one build and 5 on another. Project 13800 records a 1165 x 1165 mm structure at 1000 kg intended for 3 to 4 layers, with a rail in the base to locate a timber pallet. The numbers look comparable and are not interchangeable: different internal volumes, different gate and panel arrangements, different base construction, different goods, different floors. Taking the layer count from one and the load from another produces a combination no drawing covers and nobody has reviewed.
For the same reason, the stacking and folding illustrations in a scheme document are explanatory drawings of an arrangement, not third-party load test results. They show how boxes are meant to sit on each other; they do not certify a height, a load or a floor. If a stack height needs to be defended to a safety officer, an insurer or a customer audit, ask for the project drawing and the confirmed inputs behind it rather than a picture.
What We Need in Order to Confirm Your Stack Height
Stack height is a site design decision, so it is answered from site inputs rather than from a stock figure. Send these and the layer count can be specified together with the box:
- Floor condition along the stack line: level, any steps or pits, and the concentrated load the slab can accept at the foot positions.
- Goods weight per box, and whether it is uniform or concentrated in one area.
- Where the centre of gravity sits in a loaded box, and whether heavy and light boxes will be mixed in one stack.
- Target layer count and the clear height available, including the clearance your forklift or hand pallet truck needs to place and retrieve the top box.
- Handling method: fork entry direction, stack and unstack sequence, and whether casters are involved.
- Indoor or outdoor use, since it drives the surface treatment discussion (powder coating versus cold galvanizing) recorded in the 15730 file.
Questions Buyers Ask Before Signing Off a Stack
Does the load rating already tell me how many layers I can stack?
No. The load rating describes what one box carries; the layer count describes what the base and columns carry in a stack, plus whether the resulting height can be serviced on your floor. They are specified as two lines and confirmed together against the drawing for your project.
Can I use the layer count from another project or a competitor’s cage?
Only if the box, the goods, the floor and the handling method are the same, which in practice they are not. Layer counts in our files are project records tied to a specific build and a specific set of inputs, and mixing load and layer figures from two projects leaves you with an arrangement no drawing has reviewed.
Is a stacking illustration a load test?
No. Illustrations and renders show arrangement and intent. They are not third-party test certificates, and we do not present them as evidence of a tested stack height or capacity.
Nächster Schritt
Send your floor condition, the goods weight per box, the centre of gravity and the layer count you are targeting, and we will specify the box and the stack together instead of handing you a number to defend on your own. If the per-box load figure has not been settled yet, start with the companion article on specifying a single box’s load first, then come back to stack height. The current Mybox range and its build options are summarised on the collapsible steel stillage and pallet box page.
Benötigen Sie eine individuelle Lagerlösung?
Sprechen Sie direkt mit unseren technischen Ingenieuren. Wir bieten kostenlose Strukturplanungen, Bewertungen von Hochlast-Katalogen und schnelle B2B-Preisangebote.
Jetzt Angebot anfordern →