Double-Sided Mobile Glass Storage Rack: Technical Solution
Mgrack
Technical solution for a 2000×1120×2100 mm double-sided A-frame glass rack, 2000 kg per unit, 310 mm storage per side, rubber protection, forklift access and lifting plates.
Double-Sided Mobile Glass Storage Rack: Technical Solution
A 2000×1120×2100 mm double-sided A-frame glass rack rated at 2000 kg per unit, delivered as an assembled structure for on-site installation, with rubber strips at the goods contact points, forklift access from both sides and lifting plates on the top connecting channel. Check the 310 mm storage width per side, empty stacking and packing options before ordering.

Customer requirement analysis:
Technical solution description
Parameter table
| External dimensions | 2000×1120×2100 mm |
|---|---|
| Storage width per side | 310 mm |
| Load capacity per unit | 2000 kg |
| Unit weight (excluding rubber) | 164 kg |
| 20GP loading quantity | 36 |
| 40HQ loading quantity | 90 |
Surface treatment: powder coating; colour to be confirmed.

This product is an assembled structure and must be installed by the customer after delivery. It consists of the base (1), the A-frame upright (2) and the connecting channel (3).

Rubber strips are fitted at the contact points between the base and uprights and the goods, effectively protecting the goods.



The overall height and width requirements of the rack have to be met while also ensuring a 90° storage angle, so the storage dimension per side of our assembled structure is only 310 mm and cannot reach 400 mm. Is 310 mm acceptable? If 400 mm storage is insisted on, we can try reducing the height; this requires knowing the size of your largest glass panel and whether the rack needs to be lifted.


A forklift can enter from both sides; the forklift aisle dimensions are shown below — are they acceptable?

The top connecting channel is fitted with lifting plates, so the rack can be used for lifting.

The spacing of the bottom support structure is shown in the figure below. Does it meet the requirement for your smallest glass panel?

Do you need empty stacking? With the current structure, roughly two layers can be stacked during empty transport, mainly limited by the local height restriction at the customer's site. If empty stacking is required, please tell us the maximum permitted height.

Do you need an added pressure bar to secure the glass? This would take up storage space on one side.


After stacking, the products are packed with stretch film plus strapping (as shown below). This method creates no extra packaging cost, but it cannot fully guarantee that the paint film will not be damaged by contact between products during transport. Such damage does not affect the function of the product, only its local appearance. A more reliable wooden crate packing can also be used; the crate is calculated into the product cost strictly at our purchase price, and it reduces the loading quantity.


Finally, thank you for reading this far. Against the product information above, please consider whether it meets your operating requirements.
If you have any further questions or requirements, we will do our best to meet them and look forward to our next conversation.
Storage width, stacking height and packing choice all depend on your largest and smallest panels, unit weight, lifting requirement and aisle limits. Send these details and we will confirm the configuration before quotation. Send your requirements