Galvanized Wire Mesh Container for Parts Preparation in Semi-Outdoor and Outdoor
Stbox
Opções de contêineres de tela de arame galvanizado para armazenamento de peças ao ar livre e semiar livre: compare ≥8 μm eletrogalvanizado, cerca de 10 μm galvanizado a frio e registros de projeto de cerca de 10–40 μm, depois defina a aceitação do revestimento conforme o ambiente.
Escolha a zinc layer after defining the yard
A galvanized cage is not automatically an outdoor solution. The Stbox is a collapsible wire mesh container for industrial parts staging, but the correct surface record depends on whether your stock is indoors, under a roof, in a damp area, or fully exposed.
For a semi-outdoor or outdoor parts staging project, confirm exposure before setting the budget: rain and drainage, condensation, standing water, salt mist, chemical contact, cleaning agents, handling damage, and service expectation. Available project records include electro-galvanizing at ≥8 μm, cold-galvanizing at about 10 μm, and a cold/hot-galvanizing budget record of about 10 μm/40 μm. These are design options, not a universal Stbox specification or a generic rust-life promise.
- Q235 welded wire mesh container with collapsible frame for return and empty storage.
- 50 × 50 mm mesh recorded in the projects; check the opening against your smallest parts before ordering.
- The half-drop door supports manual access to stored components; the door side and opening direction follow the approved design.
- Forklift and pallet truck handling are documented uses in projects; confirm fork openings, load center, and equipment before full-load operation.
- The bottom reinforcement and stacking feet support repeated handling, subject to the design and load rules of the selected project.



Three coating records, three questions to resolve
≥ 8 μm RECORD
Eletrogalvanizado
A 13967 project records electro-galvanizing with a zinc layer of ≥8 μm and describes use in an open yard against rainwater. Use this record only when the project environment, exposure pattern, and inspection wording match; it is not a universal long-term outdoor guarantee.
ABOUT 10 μm RECORD
Cold-galvanized
The cold-galvanized Stbox is recorded at about 10 μm in project materials 15059 and 15217. It may be considered for general warehouse circulation or a controlled semi-outdoor area only after analyzing actual humidity, condensation, and damage risks.
ABOUT 10 / 40 μm RECORD
Hot-dip galvanized option
Budget 15059 records cold and hot galvanizing at about 10 μm / 40 μm. Confirm which value belongs to each process in the final quote. A higher thickness record may be considered for greater exposure, but by itself it does not establish a salt mist class, chemical resistance, or service life.
Solve the handling problem without hiding the corrosion decision
Visible inventory
Welded mesh allows operators to identify parts without opening a solid box. For small, delicate, or dust-sensitive components, assess whether a hollow PP plate inner liner is needed.
Fold for the return route
When empty, the cage folds to reduce storage volume and return transport. The folded height of 190 mm is recorded only for the 13967 configuration and should not be applied to all sizes.
Designed around movement
Project records support forklift and pallet truck handling. Safe operation still depends on uniform load, center of gravity, fork dimensions, and smooth lifting—not just the cage designation.
Audit the coating
Set the zinc layer target, measurement method, sampling location, local minimum value, and repair rules in the purchase documents. Do not accept "galvanized" as a complete corrosion specification.
A practical workflow for coating selection
Descreva a exposição
Tell us whether the use is indoor, covered semi-outdoor, or fully exposed; include rain, condensation, drainage, humidity, salt mist, chemicals, and washing routine.
Match the cage variant
Confirm dimensions, door side, mesh, wire, load definition, stacking arrangement, and handling equipment. The three sizes and load records in the project cannot be merged into a single standard model.
Write the zinc target
Choose the applicable project record—≥8 μm, about 10 μm, or about 10 / 40 μm—and require the final quote to state the process, target, measurement method, and acceptance limits.
Approval before production
Review the technical drawing, corrosion requirement, and inspection wording before release. For long-term outdoor, damp, salt mist, or chemical service, obtain a project-specific corrosion analysis instead of relying on a generic service-life claim.
What to confirm before choosing a galvanized cage
Can I use this wire mesh container outdoors?
Pode ser considerado para preparação de peças em exterior ou semi-exterior quando o revestimento selecionado e as condições de operação são compatíveis. Um registo 13967 descreve o uso no exterior de zincagem eletrolítica ≥8 μm contra a água da chuva. Essa descrição de projeto não deve ser ampliada como uma promessa de prevenção contra ferrugem de longa duração para todos os revestimentos ou climas.
Devo escolher zincagem eletrolítica, a frio ou por imersão a quente?
Comece pela exposição, não pelo nome do processo. Zincagem eletrolítica ≥8 μm é um registo de projeto documentado; zincagem a frio cerca de 10 μm aparece em dois registos de projeto; e o 15059 regista uma cotação a frio/por imersão a quente de cerca de 10 μm / 40 μm. Para humidade persistente, névoa salina ou produtos químicos, o processo final e o requisito de corrosão necessitam de confirmação específica do projeto.
Como definimos a espessura de zinco e a norma de aceitação?
Coloque o alvo e a unidade nos documentos da encomenda e, em seguida, defina o processo de revestimento, método de ensaio, pontos de medição, resultado local mínimo, cobertura e uniformidade, defeitos visíveis, tratamento de retoque e documento fornecido com a inspeção. Os registos atuais não estabelecem uma classe universal de névoa salina ou norma de aceitação.
As dimensões e capacidades listadas são padrão para cada Stbox?
Não. Os registos de origem descrevem 800 × 1200 × 890 mm com um registo de carga dinâmica de 1000 kg, 1000 × 800 × 840 mm com um registo de gaiola única de 1400 kg e 1050 × 1050 × 1000 mm com um registo de gaiola única de 1000 kg. São configurações de projeto separadas. Confirme o desenho, definição de carga estática ou dinâmica, distribuição, altura de empilhamento e limite de carga superior.
O que não é adequado sem confirmação adicional?
Do not use the base specification as an automatic solution for continuous immersion, stagnant water, salt spray, chemical exposure, food contact use, dust-tight containment, or safety control. Separately evaluate coating, lining, cover, closure, drainage, maintenance, and handling requirements.
What should I send for a coating recommendation?
Send the exposure location, covered or outdoor storage, wetting/drying cycle, salt or chemical contact, intended service period, cleaning method, parts and weight, required dimensions, stacking plan, handling equipment, quantity, and delivery location. We will return a coating option and inspection wording for confirmation.